BWDSW - 7173-MP SEMI-GLOSS ENAMEL-ACCENT BASE
- MSDS: BWDSW
- Manufacturer: PERVO PAINT CO
- Product Name: 7173-MP SEMI-GLOSS ENAMEL-ACCENT BASE
- National Stock Number: 8010-00N056323
Product Identification
Product ID:7173-MP SEMI-GLOSS ENAMEL-ACCENT BASE
MSDS Date:02/12/1993
FSC:8010
NIIN:00N056323
MSDS Number: BWDSW
Responsible Party
LOS ANGELES, CA 90001
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 213-758-1147
Cage: 86483
Contractor
Telephone: 213-758-1147
Cage: 86483
Ingredients
MINERAL SPIRITS
CAS: 64742-88-7
Fraction By Weight: 10-14%
OSHA PEL 500 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
SOLVENT NAPHTHA; (AROMATIC H-C SOLVENTS)
CAS: 64742-94-5
RTECS: WF3100000
Fraction By Weight: 2-4%
OSHA PEL N/K
ACGIH TLV: N/K
250
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
250
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SKIN:PROLONGED OR REPEATED
CONTACT OF PRODUCT WITH SKIN MAY CAUSE IRRITATION. EYE:DIRECT
CONTACT OF PRODUCT WITH EYES CAN CAUSE IRRITATION. INHALATION:VAPOR
OR MIST CAN CAUSE HEADACHE, NAUSEA, I RRITATION OF NOSE, THROAT AND
EYES. INGESTION:POISONOUS IF SWALLOWED. CAN EFFECT OPTIC NERVE &
OTHER (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:EFFECTS. CHRONIC:PERMANENT ADVERSE
EFFECTS ARE NOT EXPECTED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN:WASH AFFECTED AREAS W/WATER WHILE REMOVING CONTAMD
CLTHG. GET IMEMD MED ATTN. LAUNDER CONTAMD CLTHG BEFORE REUSE.
EYES:FLUSH W/GENEROUS AMTS OF WATER FOR @ LEAST 15 MINS. GET IMMED
MED ATTN. INGE ST:DO NOT INDUCE VOMIT. DILUTE W/WATER/MILK & CALL
PHYS IMMED. NEVER GIVE FLUIDS/INDUCE VOMIT IF VICTIM IS
UNCON/HAVING CONVULSIONS. INHAL:MOVE TO FRESH AIR. AID IN BRTHG, IF
NEC, & GET IMMED (SUPDAT)
Fire Fighting
Flash Point Method:TCC
Flash Point:105F,41C
Lower Limits:1.0%
Upper Limits:7.0%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . BLANK VAPOR WITH EXTINGUISH MEDIA.
Unusual Fire/Explosion Hazard:FLAMMABLE VAPOR CAN FORM EXPLOSIVE
MIXTURE WITH AIR.
Accidental Release
Spill Release Procedures:SPILLS SHOULD BE CONTAINED, SOLIDIFIED, AND
PLACED IN RCRA LICENSED FACILITY. EMPTY CNTNRS W/NO RESIDUE @ ALL
MAY BE LANDFILLED @ LICENSED FACILITY/FOR RECONDITION. REC
CRUSHING/OTHER MEANS TO PVNT UN AUTH REUSE. OTHER CNTNRS MUST BE
DISPOSED (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:SHOWER AFTER HANDLING THIS PRODUCT.
CLEAN CLOTHING SHOULD BE WORN DAILY. EYEWASH FOUNTAINS SHOULD BE
EASILY ACCESSIBLE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR
WHEN VAPORS ARE GENERATED ABOVE PERMISSABLE LIMIT.
Ventilation:LOCAL EXHAUST TO CONTROL TO RECOMMENDED PEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL GOGGLES.
Other Protective Equipment:COVERALLS, APRONS, BOOTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:MEDICAL ATTENTION. SPILL RELEASE:OF IN RCRA LICENSED
FACILITY.
Chemical Properties
Boiling Pt:B.P. Text:280F,138C
Melt/Freeze Pt:M.P/F.P Text:280F,138C
Vapor Pres:<5 @100F
Vapor Density:4.8-5.3
Spec Gravity:1.30
Evaporation Rate & Reference:<1 (BUAC =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:WHITE VISCOUS LIQUID, MILD AROMATIC ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:KEEP AWAY FROM HEAT OR DIRECT STRONG
SUNLIGHT.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE.
Disposal
Waste Disposal Methods:INCINERATE IN RCRA LICENSED FACILITY. DO NOT
DISCHARGE INTO WATERWAYS OR SEWER SYSTEMS W/OUT PROPER
AUTHORIZATION. DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.